- Provides 1500VA, 1350watt(s), 120V power / Surge Suppression is Standard
- Connector(s): Power NEMA 5-15 (F), Power NEMA 5-15 (M) / 6 Outlets
- 4.2 minute(s) Battery Runtime at Full Load / Attributes include Double conversion online, RJ-45 line protection, RJ-11 line protection
This Tripp Lite Smart Online UPS system gives you high performance power protection ideal for critical server and network equipment in datacenters, computer rooms and network closets. Its double-conversion online topology maintains perfectly regulated output power by continuously converting AC input to DC, then re-converting that output back to AC. The fully regulated sine wave AC output with +/-2% voltage regulation powers network equipment continuously, even during severe brownouts and overvoltages, all without depleting UPS battery reserves. Battery-derived AC output is maintained during power failures with zero transfer time. Other extended runtime options are available.
The interactive LCD interface reports the UPS operating mode, detailed UPS and site-power data, and a variety of UPS setup and configuration options. Highly efficient operation in the optional economy mode saves BTU heat output and energy costs. Network management interfaces support communications via USB, RS-232, contact-closure and the SNMPWEBCARD (available separately) network interface. The built-in DB-9 port offers both enhanced RS-232 data and basic contact closure monitoring ability. An HID-compliant USB interface enables integration with the built-in power management and auto shutdown features of Windows and Mac OS X.
PowerAlert monitoring software, complete cabling and Emergency Power Off (EPO) interface is included. The LED display reports UPS operating mode, line power availability, battery mode operation, inverter operation, ECO mode status and output power availability. The LED/LCD panel easily rotates for viewing in rackmount or tower configurations. The audible alarm features push-button momentary alarm-cancel and silent-mode LCD configuration options. Also featured: programmable self-test, fault-tolerant auto-bypass mode, field-replaceable hot-swappable internal batteries and optional external battery packs.
|
Connectivity
|
|
|
Communication Interface
|
Contact closure
|
|
Communication Interface
|
Serial (RS-232)
|
|
Communication Interface
|
USB
|
|
Connector
|
Power NEMA 5-15 (F)
|
|
Connector
|
Power NEMA 5-15 (M)
|
|
# Ports
|
6
|
|
General
|
|
|
Form Factor
|
2U Rackmount
|
|
Form Factor
|
Convertible Tower
|
|
Attributes
|
Double conversion online
|
|
Attributes
|
RJ-45 line protection
|
|
Attributes
|
RJ-11 line protection
|
|
Color
|
Black
|
|
Power
|
|
|
Battery Run Time (max)
|
4.2 minute(s)
|
|
Power Provided
|
1500 VA
|
|
Power Provided
|
1350 watt(s)
|
|
Power Provided
|
120 V
|
|
Surge Suppression
|
Standard
|
|
Standards
|
|
|
Compliant Standards
|
RoHS
|
|
Actual Weight
|
45.20 lb(s)
|
|
Compatibility Notes
|
Key Features
Selectable 100/110/120/127V output (120V factory preset) NEMA 5-15P input, (6) NEMA 5-15R outlets Two switched 3-outlet load banks support remote reboot or programmable load shedding options Supports 2% output voltage regulation and zero transfer time in double conversion mode Economy mode option offers enhanced efficiency, reduced power consumption and lower BTU emissions 14 minutes runtime at 50% load (675W) and 4.2 minutes at 100% load (1350W) with internal batteries BP48V24-2U (limit 1) or BP48V60RT3U (no limit) external battery packs available (some configurations require Tripp Lite's External Battery Configuration Software) LCD interface reports operating mode plus 9 selectable screens of UPS data (Load % & kW, Load % & kVA, Power factor, Input volts & Hz, Output volts & Hz, Battery volts and charge %, Minutes runtime, Capacity remaining, kW/hr. consumption) LCD interface also supports 16 screens of UPS configuration and setup options 4-post installation hardware included, Optional 2POSTRMKITWM enables 2 post rack / wallmount installation, Optional 2-9USTAND enables tower placement Single line TEL / Network surge suppression Electronic bypass maintains utility output during a variety of UPS fault conditions Frequency regulation / conversion mode offers generator-compatible frequency correction or conversion of frequency from 50 to 60Hz or 60 to 50Hz Built-in USB, RS-232, contact-closure and optional SNMPWEBCARD accessory monitoring options HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X Included PowerAlert UPS monitoring software
LEDS ALARMS & SWITCHES
LED Indicators: (7) front panel LEDs indicate line power availability, AC to DC conversion, battery mode operation, inverter mode, eco mode operation, bypass mode operation and AC output status Front panel LCD: Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, frequency, operating mode, alarm function and a variety of additional options Alarms: Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions Alarm cancel operation: Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available Switches: (2) switches control off/on power status and alarm-cancel operation; (2) additional scroll-down and scroll-up / select options enable LCD status viewing and configuration options
SURGE / NOISE SUPPRESSION
UPS AC suppression: 570 Joules UPS AC suppression response time: Instantaneous UPS Dataline suppression: (1) line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet EMI / RFI AC noise suppression: Yes
PHYSICAL
Installation form factors supported with included accessories: 4-post 19 inch rackmount (mounting rail kit included) Installation form factors supported with optional accessories: 2-post rackmount (2POSTRMKITWM); Wallmount (2POSTRMKITWM); Tower (2-9USTAND) Primary form factor: Rackmount Installed whole system total rack space height (rack spaces): 2U Secondary form factor: Tower (requires 2-9USTAND, available separately) UPS housing material: Steel Cooling method: Fan
|
|
Contents
|
UPS, PowerAlert software, USB serial EPO cabling, 4-post rackmount kit, documentation
|
|
Physical Dimensions
|
3.5"h x 17.5"w x 18.5"d
|
|
Ports/Connectors
|
Built-in UPS output receptacles: (6) 5-15R outlets Built-in controllable switched load banks: Two switchable three-outlet 5-15R load banks UPS input connection type: 5-15P Input circuit breaker: 20A UPS Input cord length: 10ft/3m
|
|
Power Notes
|
Output
Output Capacity: 1500VA/1350W Output power factor: 0.9 Output Capacity Details: ON LINE MODE - Maximum output capacity ratings are reduced for some nominal voltage settings (127/120V 1350 watts / 115V 1215 watts / 110V 1148 watts / 100V 1080 watts); FREQUENCY REGULATION / CONVERSION MODE - Maximum output ratings are reduced in frequency regulation / conversion mode (127/120V 945 watts / 115V 850 watts / 110V 804 watts / 100V 756 watts). Crest Factor: 3:1 Nominal Output Voltages Supported: 100V, 110V, 115V, 120V, 127V Nominal Voltage details: 120V factory-default nominal voltage Frequency compatibility: 50/60Hz (auto-selectable); supports 50 to 60Hz and 60 to 50Hz conversion Frequency compatibility details: ON LINE MODE - Output frequency is automatically configured to match nominal input frequency on startup; Output matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. FREQUENCY REGULATION / CONVERSION MODE - Output is regulated to +/-0.05Hz of selected output frequency input is 40 to 70Hz; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. BATTERY MODE - Output is regulated to +/-0.05Hz. Output voltage regulation (line mode): +/- 2% Output voltage regulation (Economy line mode): +/- 10% Output voltage regulation (Battery mode): +/- 3% Output AC waveform (AC mode): Pure Sine wave Output AC waveform (battery mode): Pure Sine wave
Input Rated input current (at maximum load): 12A Nominal Input Voltages Supported: 100V AC; 110V AC; 115V AC; 120V AC; 127V AC Nominal input voltage description: 120V factory default Recommended Electrical Service: 15A 120V
Battery
Full load runtime: 4.2 min. (1350w) Half load runtime: 14 min. (675w) Expandable battery runtime: Extended runtime supported via optional external battery packs External battery pack compatibility: BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible) Expandable runtime description: Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software DC system voltage: 48VDC Battery recharge rate (included batteries): Less than 3 hours recharge to 90% Replacement battery cartridge (internal UPS battery replacement): RBC94-2U Battery Access: Front panel battery access Battery replacement description: Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage regulation description: Online, double-conversion power conditioning maintains 2% output voltage regulation during brownouts and overvoltages Overvoltage correction: Corrects overvoltages to 150V (0-100% load) Undervoltage correction: Corrects undervoltages to 100V at full load (90V at 100V nominal) Severe undervoltage correction: Corrects brownouts to 70V (70% load) & 55V (33% load)
|
|
Returns Policy
|
This product is subject to our return policy. Please see our complete return policy for details.
|
|
Warranty - Labor
|
2 Years
|
|
Warranty - Parts
|
2 Years
|
|
Warranty Details
|
Connected Equipment Insurance (U.S., Canada & Puerto Rico): $250, 000
|
| Description |
Availability |
Unit Price |
|
|
|
Call for Availability
|
$41.26
|
Qty:
5094309
|
|
|
|
Call for Availability
|
$113.49
|
Qty:
5093381
|
http://www.pcconnection.com/IPA/Shop/Product/Detail.htm?sku=14474531#BVSecondaryCustomerRatings