- Provides 3000VA, 2700watt(s), 120V power / Surge Suppression is Standard
- Connector(s): Power NEMA L5-30 (F), Power NEMA L5-30 (M), Power NEMA 5-15 (F), Power NEMA 5-20 (F) / 9 Outlets
- 4 minute(s) Battery Runtime at Full Load / Attributes include Double conversion online, RJ-11 line protection, RJ-45 line protection
Tripp Lite Smart Online UPS systems offer high performance power protection ideal for critical server and network equipment in datacenters, computer rooms and network closets. Online, double-conversion Uninterruptible Power Supply (UPS) maintains perfectly regulated output power by continuously converting raw AC input to DC, then re-converting output back to AC. Fully regulated sine wave AC output with +/-2% voltage regulation powers network equipment continuously, even during severe brownouts and overvoltages, all without depleting UPS battery reserves. Maintains battery-derived AC output during power failures with zero transfer time. Extended runtime options available. Interactive LCD interface reports UPS operating mode, detailed UPS and site-power data, plus enables a variety of UPS setup and configuration options. Highly efficient operation in optional economy mode saves BTU heat output and energy costs. Network management interfaces support communications via USB, RS-232, contact-closure and optional SNMPWEBCARD network interface. Built-in DB9 port offers both enhanced RS-232 data and basic contact closure monitoring ability. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. LED display reports UPS operating mode, line power availability, battery mode operation, inverter operation, ECO mode status and output power availability. Audible alarm with push-button momentary alarm-cancel and silent-mode LCD configuration options. Programmable self-test. Fault-tolerant auto-bypass mode. Field-replaceable, hot-swappable internal batteries and external battery packs.
|
Connectivity
|
|
|
Communication Interface
|
USB
|
|
Communication Interface
|
Serial (RS-232)
|
|
Communication Interface
|
Contact closure
|
|
Connector
|
Power NEMA L5-30 (F)
|
|
Connector
|
Power NEMA L5-30 (M)
|
|
Connector
|
Power NEMA 5-15 (F)
|
|
Connector
|
Power NEMA 5-20 (F)
|
|
# Ports
|
9
|
|
General
|
|
|
Color
|
Black
|
|
Form Factor
|
3U Rackmount
|
|
Attributes
|
Double conversion online
|
|
Attributes
|
RJ-11 line protection
|
|
Attributes
|
RJ-45 line protection
|
|
Power
|
|
|
Battery Run Time (max)
|
4 minute(s)
|
|
Power Provided
|
3000 VA
|
|
Power Provided
|
2700 watt(s)
|
|
Power Provided
|
120 V
|
|
Surge Suppression
|
Standard
|
|
Actual Weight
|
74.00 lb(s)
|
|
Compatibility Notes
|
Features
Selectable 100/110/120/127V output (120V factory preset) NEMA L5-30P input, 4 NEMA 5-15/20R, 4 5-15R & 1 L5-30R outlets Two switched 4-outlet load banks support remote reboot or programmable load shedding options Supports 2% output voltage regulation and zero transfer time in double conversion mode Economy mode option offers enhanced efficiency, reduced power consumption and lower BTU emissions 11 minutes runtime at 50% load (1350W) and 4 minutes at 100% load (2700W) with internal batteries BP72V15-2U (limit 1) or BP72V28RT3U (no limit) external battery packs available (some configurations require Tripp Lite's External Battery Configuration Software) LCD interface reports operating mode plus 9 selectable screens of UPS data (Load percentage, kW & kVA, Power factor, Input voltage & frequency, Output voltage & frequency, Battery voltage and charge percentage, Minutes runtime, Capacity remaining and Kw/hr. consumption) LCD interface also supports 16 screens of UPS configuration and setup options 4-post installation hardware included, Optional 2POSTRMKITHD enables 2-post rack installation Single line TEL / Network surge suppression Electronic bypass maintains utility output during a variety of UPS fault conditions Frequency regulation / conversion mode offers generator-compatible frequency correction or conversion of frequency from 50 to 60Hz or 60 to 50Hz Built-in USB, RS-232, contact-closure and optional SNMPWEBCARD accessory monitoring options HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X Included PowerAlert UPS monitoring software
LEDS ALARMS & SWITCHES
LED Indicators: (7) front panel LEDs indicate line power availability, AC to DC conversion, battery mode operation, inverter mode, eco mode operation, bypass mode operation and AC output status Front panel: Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, frequency, operating mode, alarm function and a variety of additional options Alarms: Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions Alarm cancel operation: Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available Switches: (2) switches control off/on power status and alarm-cancel operation; (2) additional scroll-down and scroll-up / select options enable LCD status viewing and configuration options
SURGE / NOISE SUPPRESSION
UPS AC suppression rating: 570 Joules UPS AC suppression response time: Instantaneous UPS Dataline suppression: (1) line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet EMI / RFI AC noise suppression: Yes
PHYSICAL
Installation form factors supported with included accessories: 4-post 19 inch rackmount (mounting rail kit included) Installation form factors supported with OPTIONAL accessories: 2-post rackmount (2POSTRMKITHD) Primary form factor: Rackmount
|
|
Contents
|
UPS, software, USB/Serial/EPO cabling, 4-post rackmount kit, documentation
|
|
Physical Dimensions
|
5.2"h x 17.5"w x 26"d
|
|
Ports/Connectors
|
Built-in UPS output receptacles: (4) 5-15R outlets; (4) 5-15/20R outlets; (1) L5-30R outlets Built-in controllable switched load banks: Two switchable four-outlet load banks UPS input connection type: L5-30P UPS Input cord length: 10ft (3m)
|
|
Power Notes
|
OUTPUT
Output Capacity: 3000VA/2700W Output power factor: 0.9 Output Capacity Details: ON LINE MODE - Maximum output capacity ratings are reduced for some nominal voltage settings (127/120V 2700 watts / 115V 2430 watts / 110V 2295 watts / 100V 2160 watts); FREQUENCY REGULATION / CONVERSION MODE - Maximum output ratings are reduced in frequency regulation / conversion mode (127/120V 1890 watts / 115V 1701 watts / 110V 1606 watts / 100V 1512 watts). Crest Factor: 3:1 Nominal Output Voltages Supported: 100V; 110V; 115V; 120V; 127V Nominal Voltage details: 120V factory-default nominal voltage Frequency compatibility: 50/60 Hz (auto-selectable); Supports 50 to 60 Hz and 60 to 50 Hz conversion Frequency compatibility details: ON LINE MODE - Output frequency is automatically configured to match nominal input frequency on startup; Output matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. FREQUENCY REGULATION / CONVERSION MODE: Output is regulated to +/-0.05Hz of selected output frequency input is 40 to 70Hz; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. BATTERY MODE: Output is regulated to +/-0.05Hz. Output voltage regulation (line mode): +/- 2% Output voltage regulation (Economy line mode): +/- 10% Output voltage regulation (Battery mode): +/- 3% Output AC waveform (AC mode) Pure Sine wave Output AC waveform (battery mode) Pure Sine wave
INPUT
Rated input current (at maximum load) 24A Nominal Input Voltages Supported: 100V AC; 110V AC; 115V AC; 120V AC; 127V AC Nominal input voltage description: 120V factory default Input circuit breaker: 40A Recommended Electrical Service: 30A, 120V
BATTERY
Full load runtime: 4 min. (2700w) Half load runtime: 11 min. (1350w) Expandable battery runtime: Extended runtime supported via optional external battery packs External battery pack compatibility: BP72V15-2U (limit 1); BP72V28RT-3U (multi-pack compatible) Expandable runtime description: Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software, see manual for details DC system voltage: 72VDC Battery recharge rate (included batteries): Less than 3 hours recharge to 90% Replacement battery cartridge (internal UPS battery replacement): RBC96-3U Battery Access: Front panel battery access Battery replacement description: Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage regulation description: Online, double-conversion power conditioning maintains 2% output voltage regulation during brownouts and overvoltages Overvoltage correction: Corrects overvoltages to 150V (0-100% load) Undervoltage correction: Corrects undervoltages to 100V at full load (90V at 100V nominal) Severe undervoltage correction: Corrects brownouts to 70V (70% load) & 55V (33% load)
|
|
Returns Policy
|
This product is subject to our return policy. Please see our complete return policy for details.
|
|
Warranty - Labor
|
2 Years
|
|
Warranty - Parts
|
2 Years
|
|
Warranty Details
|