- Provides 2600VA, 2100watt(s), 120V power / Surge Suppression is Standard
- Connector(s): Power NEMA 5-15 (F), Power NEMA 5-20 (F) Power NEMA 5-20 (M), Power NEMA L5-20 (F) / 9 Outlets
- 4 minute(s) Battery Runtime at Full Load / Attributes include Line interactive, Automatic voltage regulation (AVR)
This is Tripp Lite's 2600VA line interactive UPS system for server, network and telecommunications equipment. The 2U rackmount or tower form factor has an installed depth of only 19 inches. Its high 96% line-power efficiency rating reduces energy consumption and BTU heat output. Expandable battery runtime can be achieved with the optional BP48V24-2U and BP48V60RT-3U external battery packs. The Uninterruptible Power Supply (UPS) switches to battery-derived AC output during power failures and extreme voltage variations, and Line interactive Automatic Voltage Regulation (AVR) provides two levels of voltage boost during brownouts and one level of voltage cut during overvoltages to maintain its regulated 120VAC output over an input range of 83-145V.
Output connectors include (4) 5-15R, (4) 5-15/20R and one L5-20R receptacles with an attached 5-20P input plug and 10-foot power cord. Network management interfaces support communications via USB, DB9 serial and an SNMPWEBCARD slot. The HID-compliant USB interface enables full integration with the built-in power management and auto shutdown features of Windows and Mac OS X. Simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all 3 network interfaces at once is supported. PowerAlert monitoring software and complete cabling is included. Also featured: an Emergency Power Off (EPO) interface, integrated 3-bank PDU switching to support load shedding and remote-reboot of connected equipment, 3-stage metered current monitoring,d battery charge status LEDs, utility power and voltage regulation LEDs, audible alarm and a self-test function. 4-post rackmount accessories are included.
|
Connectivity
|
|
|
Communication Interface
|
Contact closure
|
|
Communication Interface
|
USB
|
|
Communication Interface
|
Serial (RS-232)
|
|
Connector
|
Power NEMA 5-15 (F)
|
|
Connector
|
Power NEMA 5-20 (M)
|
|
# Ports
|
9
|
|
Connector
|
Power NEMA L5-20 (F)
|
|
Connector
|
Power NEMA 5-20 (F)
|
|
General
|
|
|
Attributes
|
Automatic voltage regulation (AVR)
|
|
Attributes
|
Line interactive
|
|
Form Factor
|
2U Rackmount
|
|
Form Factor
|
Tower
|
|
Power
|
|
|
Power Provided
|
2600 VA
|
|
Power Provided
|
2100 watt(s)
|
|
Power Provided
|
120 V
|
|
Surge Suppression
|
Standard
|
|
Battery Run Time (max)
|
4 minute(s)
|
|
Actual Weight
|
64.00 lb(s)
|
|
Compatibility Notes
|
LEDS ALARMS & SWITCHES
LED Indicators: (5) LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status Alarms: Audible alarm indicates power-failure, overload and low-battery conditions Alarm cancel operation: Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status Switches: (2) Switches control off/on power status and alarm-cancel/self-test operation
SURGE / NOISE SUPPRESSION
UPS AC suppression: 480 Joules UPS AC suppression response time: Instantaneous EMI / RFI AC noise suppression: Yes
PHYSICAL
Installation form factors supported with included accessories: 4-post 19" rackmount (mounting rail kit included) Installation form factors supported with OPTIONAL accessories: 2-post rackmount (2POSTRMKITWM); Wallmount (2POSTRMKITWM); Tower (2-9USTAND) Primary form factor: Rackmount Secondary form factor: Tower (requires 2-9USTAND, available separately)
COMMUNICATIONS
Communications interface: USB (HID enabled); DB9 Serial; Contact closure Network monitoring port description: Supports detailed monitoring of UPS and site power conditions; (1) USB port and (1) DB9 serial contact closure port PowerAlert software: Included Communications cable: USB and DB9 cabling included WatchDog compatibility: Supports Watchdog application, OS and hard-reboot restart options for remote applications
LINE / BATTERY TRANSFER
Transfer time: 5 milliseconds Low voltage transfer to battery power (setpoint): 83V High voltage transfer to battery power (setpoint): 145V
SPECIAL FEATURES
Grounding lug: Back panel grounding lug Cold Start (startup in battery mode during a power failure): Cold-start operation supported High availability UPS features: Hot swappable batteries Green & high efficiency features: Greater than 95% efficiency - GREEN UPS; Individually controllable load banks
CERTIFICATIONS
UPS Certifications: Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI); RoHS (Reduction of Hazardous Substances)
|
|
Contents
|
UPS System, PowerAlert Software and cabling, 4-post rackmount installation hardware, documentation
|
|
Physical Dimensions
|
3.5"h x 17.5"w x 19"d
|
|
Ports/Connectors
|
(1) NEMA L5-20R outlet (4) NEMA 5-15R outlets (4) NEMA 5-15/20R outlets (1) NEMA 5-20P input plug, 10ft cord (2) USB management port (2) DB-9 management port
|
|
Power Notes
|
OUTPUT
Output Capacity: 2600VA/2100W Output power factor 0.8 Output Capacity Details: Output capacity de-rates to 1600 watts with external battery packs connected Nominal Output Voltage Supported: 120V Frequency compatibility: 60Hz Output voltage regulation (line mode): -18%, +8% Output voltage regulation (Battery mode): +/- 5% Built-in controllable switched load banks: Three switchable single-outlet 5-15R load banks Output circuit breaker: 15A breaker protects 5-15R, 20A breaker protects 5-15/20R, L5-20R is unbreakered Output AC waveform (AC mode): Sine wave Output AC waveform (battery mode): Sine wave
INPUT
Rated input current (at maximum load): 24A (with user-supplied L5-30P plug), 16A (with factory 5-20P plug) Nominal Input Voltage Supported: 120VAC Input circuit breaker: 30A Recommended Electrical Service: 20-30A 120V
BATTERY
Full load runtime: 4 min. (2100w) Half load runtime: 11 min. (1050w) Expandable battery runtime: Extended runtime supported via optional external battery packs External battery pack compatibility: BP48V24-2U (limit 1); BP48V60RT3U (multi-pack compatible) DC system voltage: 48VDC Battery recharge rate (included batteries): Less than 4.5 hours from 10% to 90% Replacement battery cartridge (internal UPS battery replacement): RBC94-2U Battery Access: Front panel battery access door Battery replacement description: Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage regulation description: Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83V to 147V Overvoltage correction: Input voltages between 127 and 147V are reduced by 12% Undervoltage correction: Input voltages between 95 and 104V are boosted by 12% Severe undervoltage correction: Input voltages between 83 and 94V are boosted by 24%
|
|
Returns Policy
|
This product is subject to our return policy. Please see our complete return policy for details.
|
|
Warranty - Labor
|
2 Years
|
|
Warranty - Parts
|
2 Years
|
|
Warranty Details
|
2-year warranty, 3 year with registration. Note: registration is required for 3-year warranty. Connected Equipment Insurance (U.S., Canada & Puerto Rico) $250, 000 Ultimate Lifetime Insurance
|
| Description |
Availability |
Unit Price |
|
|
|
Call for Availability
|
$82.54
|
Qty:
5094317
|
|
|
|
Call for Availability
|
$226.99
|
Qty:
5093390
|