The 6000 Watt AC power supply features combined Mode Power Resiliency as an extension of the traditional combined mode power-supply behavior. Each power supply contains two smaller power supplies (called sub-units). In Combined Mode Power Resiliency the system relies only on power from three out of four power-supply sub-units. When using 220 VAC, this feature helps ensure that maximum power is available while the switch is protected against a single input power failure or sub-unit component failure.
The 6000 Watt AC Power Supply also supports true output power consumption monitoring capability.
|
Power
|
|
|
Power Provided
|
6000 watt(s)
|
|
Contents
|
Unit, documentation
|
|
Power Notes
|
Integrated PoE: Yes (up to 4800W) IEEE 802.3af compliant: Yes Input current (rated): (2) 12A at 100VAC or (2) 16A at 200VAC Output current (data): 12V at 186.9A, 3.3V at 12.5A Output current (PoE): -50V at 100.0A (200V), -50V at 38.5A (120V) Output power redundant mode (data): 2200W + 40W Output power redundant mode (PoE): 4800W (220V), 1850W (110V) Output power combined mode (data): 4400W Output power combined mode (PoE): 8700W (220V), 3360W (110V) Holdup time: 20ms Number of 802.3af class 2 powered devices supported: 384 (200V), 245 (100V) Number of 802.3af classes 0 and 3 powered devices supported: 289 (200V), 111 (100V)
|
|