          • Provides 900VA, 480watt(s), 120V power
          • Surge Suppression is Standard
          • Connector(s): Power NEMA 5-15 (F), Power NEMA 5-15 (M)
          • 9 Outlets
          • 2.20 minute(s) Battery Runtime at Full Load
          • Attributes include Standby

          Ordering Information

          The Back-UPS battery backup offers guaranteed power and surge protection for wireless networks, computers, gaming consoles and other electronics in your home or business. Models supply battery backup during outages and unsafe voltage fluctuations, as well as provide protection from damaging surges and spikes. They are available in 'tower' or 'floor' styles, and together with a variety of standard features, they are the perfect choice to protect your data and keep you connected.
          Collapse & Return to Top
          Actual Weight 9.04 lb(s)
          Compatibility Notes BN900M Features

          Adjustable voltage sensitivity - Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
          Audible alarms - Provides notification of changing utility power and UPS power conditions.
          Automatic self-test - Periodic battery self-test ensures early detection of a battery that needs to be replaced.
          Battery failure notification - Provides early-warning fault analysis on batteries enabling timely preventive maintenance.
          Building Management Integration - Send alarms and data points to your building management system, allowing you to manage critical building infrastructure from a single system.
          Cold-start capable - Provides temporary battery power when the utility power is out.
          Disconnected battery notification - Warns when a battery is not available to provide backup power.
          Hot-swappable batteries - Ensures clean, uninterrupted power to protected equipment while batteries are being replaced.
          Simple battery replacement - Increases UPS availability by allowing quick, easy battery replacement.
          Transformer Block Spacing - Connect bulky transformer block plugs without covering up other outlets.
          USB connectivity - Provides management of the UPS via a USB port.
          # Ports 9
          Communication Interface USB
          Connector Power NEMA 5-15 (F), Power NEMA 5-15 (M)
          Contents UPS, USB cable, documentation
          Attributes Standby
          Color Black
          Form Factor Desktop
          Physical Dimensions 5.5"h x 12.9"w x 4.1"d
          Ports/Connectors Output Connections: (6) NEMA 5-15R (Battery Backup), (3) NEMA 5-15R (Surge Only)
          Input Connection: NEMA 5-15P
          Cord Length: 5ft (1.52m)
          Number of Power Cords: (1)

          Communications & Management

          Interface Port: USB
          Control panel: LED status display with On Line, On Battery, Replace Battery and Building Wiring Fault
          Audible Alarm: Alarm when On Battery, Distinctive Low Battery Alarm, Overload continuous tone alarm
          Battery Run Time (max) 2.20 minute(s)
          Power Provided 120 V, 480 watt(s), 900 VA
          Surge Suppression Standard
          Power Notes Output

          Output power capacity: 480 Watts/900VA
          Max Configurable Power: 480 Watts/900VA
          Nominal Output Voltage 120V
          Output Frequency (sync to mains): 50/60Hz +/-1Hz
          Topology: Standby
          Waveform type: Stepped approximation to a sinewave
          Transfer Time: 6ms typical, 10ms maximum


          Nominal Input Voltage: 120V
          Input frequency: 50/60Hz +/- 3Hz (auto sensing)
          Input voltage range for main operations: 92 - 139V

          Batteries & Runtime

          Battery type: Maintenance-free sealed Lead-Acid battery with suspended electrolyte, leakproof
          Typical recharge time: 8 hours
          Expected Battery Life: 2 - 5 years
          Battery Volt-Amp-Hour Capacity: 84
          Runtime, Full Load: 2.2 minutes (480W)
          Runtime, Half Load: 9.6 minutes (240W)

          Surge Protection and Filtering

          Surge energy rating: 354 Joules
          Returns Policy This product is subject to our return policy. Please see our complete return policy for details.
          Compliant Standards Energy Star, REACH, RoHS
          UNSPSC 39121011
          Warranty - Labor 3 Years
          Warranty - Parts 3 Years
          Collapse & Return to Top
          Add this product to your cart with selected accessories
          Add To Cart
          Battery Backup (UPS) (3 Products)
          Add this product to your cart with selected accessories
          Add To Cart
          Collapse & Return to Top
          Description Availability Unit Price  
          View All Warranties
          Collapse & Return to Top

          Our Accessibility Policy

          We endeavor to make our website accessible to any and all users. Please contact us toll-free at 800-998-4388 if you need assistance with navigating our blog, website, or placing an order. We appreciate your business and are happy to answer any questions that you may have.