Connection Clearance Center. Shop Now!

Connected Interactive eCatalog

Messages

          Tripp Lite Monitored PDU, 380 400V Input 220 230V 11kW 3-Ph, 0U, IEC-309 16A Red, (21) C13 (3) C19, 10ft Cord

          More From: Tripp Lite
          Item #: 31643877
          Mfr. Part#: PDU3XVSR10G16
          Availability: Temporarily Out-of-Stock
          Est. Ship: Call for next available delivery

            Ordering Information

            Price:
            $995.80
             
            Tripp Lite 3 phase Switched PDU / Power Distribution Unit offers advanced network control and monitoring with the ability to turn on, turn off, recycle or lock-out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption per-phase or per-receptacle. PowerAlert interface supports remote control and custom notification of user-specified conditions via email, secure web, SNMP, Telnet or SSH interface. Individually switched outlets can be controlled in real-time to remotely reboot unresponsive network hardware, or be custom programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of unauthorized hardware. PDU output current consumption in amps per-phase or per-receptacle can be displayed locally via visual meter or remotely via web/network interface to warn of potential overloads before critical IT mains or branch breakers trip.
            Collapse & Return to Top
            Actual Weight 12.40 lb(s)
            Compatibility Notes Features

            11kW 3 phase 380/400V input, 220/230V output Monitored Power Distribution Unit (PDU) with built-in web/network interface
            Attached IEC-309 Red 16A (3P+N+E) 380/400V 3 phase input plug with 0.9m cord
            0U/178cm vertical form factor supports installation in 2- or 4-post equipment racks
            (24) total 220/230V outlets (21 C13, 3 C19) arranged in 3 single-phase output load banks
            Supports power-on, power-off or reboot of each outlet on a real-time or programmable basis
            Enables reboot of locked equipment, custom power-on/power-off sequences, load-shedding of optional loads and disabling unused outlets
            Network interface provides PDU control and data regarding input voltage and per-phase load levels with +/-1% billing-grade accuracy
            Digital display with scroll-buttons supports per-outlet or per-phase load levels, IP-address self-identification and 180 degree display rotation
            Supports user-specified alarm notification thresholds
            In-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors
            DHCP/Manual configuration support
            10/100Mbps auto-sensing
            Real-time clock backup maintains the time of day and date even if the PDU is not powered on
            Tiered access privileges allow an administrator and a guest to login via web browser
            Alert notifications via email or SNMP traps offer immediate event notification
            Firmware upgrade ability supports future product enhancements
            Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols
            Fully compatible with FREE PowerAlert Network Management System / NMS Software
            Included cord retention brackets
            Toolless mounting supported in button-mount compatible racks, plus nut-and-bolt mounting brackets for other mounting applications (set of 2 9mm buttons pre-installed, 2 9mm and 4 6mm spare buttons included)

            USER INTERFACE, ALERTS & CONTROLS

            Reported Load Segments: Supports local monitoring of current for each output phase (16A balanced max per output load banks L1, L2 and L3); BANK "L1" is powered by L1-N (outlets 1-12); BANK "L2" is powered by L2-N (outlets 13-24); BANK "L3" is powered by L3-N (outlets 25-36)
            Front Panel LCD: Digital display reports output load level in amps separately for each output phase; Can also be used to scroll the configured IP address
            Front Panel LEDs: Set of 3 LEDs (L1, L2, L3) indicate the output load segment the digital current display is reporting

            Switches:SELECT switch advances the digital display and LED to report power consumption for load segments L1, L2 and L3 (short press); SELECT switch also rotates the local display 90 degrees for overhead power input (long press); SCROLL IP button scrolls the configured IP address (long press)
            Connectivity
            # Ports 24
            Connector Power IEC 320 EN 60320 C13 (F), Power IEC 320 EN 60320 C19 (F)
            Contents PDU, pre-installed mounting buttons, cord retention brackets, rack mounting brackets, documentation
            General
            Attributes Metered
            Color Black
            Form Factor 0U Rackmount
            Physical Dimensions 70"h x 2.2"w x 3.3"d
            Ports/Connectors Output Receptacles: (21) C13; (3) C19
            Outlet Type: IEC-C13, IEC-C19
            PDU Plug Type: IEC-309 16/20A RED (3P+N+E)
            Input Cord Length: 10ft
            Power
            Power Provided 11 kW
            Power Notes Specifications

            PDU Type: Monitored

            OUTPUT

            Output Capacity Details: 11.5kW (415/240V), 11.1kW (400/230V), 10.5kW (380/220V) total capacity; 16A max per output phase (L1-L2, L2-L3, L3-L1); 16A max per C19 outlet; 10A max per C13 outlet
            Frequency Compatibility: 50/60Hz
            Output Nominal Voltage: 220 (380V input); 230 (400V input)
            Overload Protection: n/a

            INPUT

            PDU Input Voltage: 380; 400V
            Recommended Electrical Service: 16A 400/230V with IEC309 16A Red (3P+N+E) outlet
            Maximum Input Amps: 16A
            Input Phase: 3-Phase
            Returns Policy This product is subject to our return policy. Please see our complete return policy for details.
            Standards
            Compliant Standards EN 60950-1, FCC Class A certified, RoHS
            UNSPSC 39121017
            Warranty - Labor 2 Years
            Warranty - Parts 2 Years
            Collapse & Return to Top

            Our Accessibility Policy


            We endeavor to make our website accessible to any and all users. Please contact us toll-free at 800-998-4388 if you need assistance with navigating our blog, website, or placing an order. We appreciate your business and are happy to answer any questions that you may have.