          • Provides 2200VA, 1800watt(s), 120V power
          • Surge Suppression is Standard
          • Connector(s): Power NEMA 5-20 (F), Power NEMA 5-20 (M)
          • 6 Outlets
          • 4 minute(s) Battery Runtime at Full Load
          • Attributes include Double conversion online, RJ-45 line protection, RJ-11 line protection

          Ordering Information

          Price:
           
          This Tripp Lite Smart Online UPS system gives you high performance power protection ideal for critical server and network equipment in datacenters, computer rooms and network closets. Its double-conversion online topology maintains perfectly regulated output power by continuously converting AC input to DC, then re-converting that output back to AC. The fully regulated sine wave AC output with +/-2% voltage regulation powers network equipment continuously, even during severe brownouts and overvoltages, all without depleting UPS battery reserves. Battery-derived AC output is maintained during power failures with zero transfer time. Other extended runtime options are available.

          The interactive LCD interface reports the UPS operating mode, detailed UPS and site-power data, and a variety of UPS setup and configuration options. Highly efficient operation in the optional economy mode saves BTU heat output and energy costs. Network management interfaces support communications via USB, RS-232, contact-closure and the SNMPWEBCARD (available separately) network interface. The built-in DB-9 port offers both enhanced RS-232 data and basic contact closure monitoring ability. An HID-compliant USB interface enables integration with the built-in power management and auto shutdown features of Windows and Mac OS X.

          PowerAlert monitoring software, complete cabling and Emergency Power Off (EPO) interface is included. The LED display reports UPS operating mode, line power availability, battery mode operation, inverter operation, ECO mode status and output power availability. The LED/LCD panel easily rotates for viewing in rackmount or tower configurations. The audible alarm features push-button momentary alarm-cancel and silent-mode LCD configuration options. Also featured: programmable self-test, fault-tolerant auto-bypass mode, field-replaceable hot-swappable internal batteries and optional external battery packs.
          Collapse & Return to Top
          Actual Weight 48.50 lb(s)
          Compatibility Notes Key Features

          Selectable 100/110/120/127V output (120V factory preset)
          NEMA 5-20P input, (6) NEMA 5-15/20R and (1) L5-20R outlets
          Two switched 3-outlet load banks support remote reboot or programmable load shedding options
          Supports 2% output voltage regulation and zero transfer time in double conversion mode
          Economy mode option offers enhanced efficiency, reduced power consumption and lower BTU emissions
          12 minutes runtime at 50% load (900W) and 4 minutes at 100% load (1800W) with internal batteries
          BP48V24-2U (limit 1) or BP48V60RT3U (no limit) external battery packs available (some configurations require Tripp Lite's External Battery Configuration Software)
          LCD interface reports operating mode plus 9 selectable screens of UPS data (Load % & kW, Load % & kVA, Power factor, Input volts & Hz, Output volts & Hz, Battery volts and charge %, Minutes runtime, Capacity remaining, kW/hr. consumption)
          LCD interface also supports 16 screens of UPS configuration and setup options
          4-post installation hardware included, Optional 2POSTRMKITWM enables 2 post rack / wallmount installation, Optional 2-9USTAND enables tower placement
          Single line TEL / Network surge suppression
          Electronic bypass maintains utility output during a variety of UPS fault conditions
          Frequency regulation / conversion mode offers generator-compatible frequency correction or conversion of frequency from 50 to 60Hz or 60 to 50Hz
          Built-in USB, RS-232, contact-closure and optional SNMPWEBCARD accessory monitoring options
          HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
          Included PowerAlert UPS monitoring software

          LEDS ALARMS & SWITCHES

          LED Indicators: (7) front panel LEDs indicate line power availability, AC to DC conversion, battery mode operation, inverter mode, eco mode operation, bypass mode operation and AC output status
          Front panel LCD: Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, frequency, operating mode, alarm function and a variety of additional options
          Alarms: Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
          Alarm cancel operation: Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available
          Switches: (2) switches control off/on power status and alarm-cancel operation; (2) additional scroll-down and scroll-up / select options enable LCD status viewing and configuration options

          SURGE / NOISE SUPPRESSION

          UPS AC suppression: 570 Joules
          UPS AC suppression response time: Instantaneous
          UPS Dataline suppression: (1) line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet
          EMI / RFI AC noise suppression: Yes

          PHYSICAL

          Installation form factors supported with included accessories: 4-post 19 inch rackmount (mounting rail kit included)
          Installation form factors supported with optional accessories: 2-post rackmount (2POSTRMKITWM); Wallmount (2POSTRMKITWM); Tower (2-9USTAND)
          Primary form factor: Rackmount
          Installed whole system total rack space height (rack spaces): 2U
          Secondary form factor: Tower (requires 2-9USTAND, available separately)
          UPS housing material: Steel
          Cooling method: Fan
          Connectivity
          # Ports 6
          Communication Interface Contact closure, Serial (RS-232), USB
          Connector Power NEMA 5-20 (F), Power NEMA 5-20 (M)
          Contents UPS, PowerAlert software, USB serial EPO cabling, 4-post rackmount kit, documentation
          General
          Attributes Double conversion online, RJ-11 line protection, RJ-45 line protection
          Color Black
          Form Factor 2U Rackmount, Convertible Tower
          Physical Dimensions 3.5"h x 17.5"w x 19d
          Ports/Connectors Built-in UPS output receptacles: (6) 5-15/20R outlets
          Built-in controllable switched load banks: Two switchable three-outlet 5-15/20R load banks
          UPS input connection type: 5-15P
          Input circuit breaker: 20A
          UPS Input cord length: 10ft/3m
          Power
          Battery Run Time (max) 4 minute(s)
          Power Provided 120 V, 1800 watt(s), 2200 VA
          Surge Suppression Standard
          Power Notes Output

          Output Capacity: 2200VA/1800W
          Output power factor: 0.82
          Output Capacity Details: ON LINE MODE - Maximum output capacity ratings are reduced for some nominal voltage settings (127/120V 1800 watts / 115V 1620 watts / 110V 1530 watts / 100V 1440 watts). FREQUENCY REGULATION / CONVERSION MODE - Maximum output ratings are reduced in frequency regulation / conversion mode (127/120V 1260 watts / 115V 1134 watts / 110V 1071 watts / 100V 1008 watts)
          Crest Factor: 3:1
          Nominal Output Voltages Supported: 100V, 110V, 115V, 120V, 127V
          Nominal Voltage details: 120V factory-default nominal voltage
          Frequency compatibility: 50/60Hz (auto-selectable); supports 50 to 60Hz and 60 to 50Hz conversion
          Frequency compatibility details: ON LINE MODE - Output frequency is automatically configured to match nominal input frequency on startup; Output matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. FREQUENCY REGULATION / CONVERSION MODE - Output is regulated to +/-0.05Hz of selected output frequency input is 40 to 70Hz; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. BATTERY MODE - Output is regulated to +/-0.05Hz.
          Output voltage regulation (line mode): +/- 2%
          Output voltage regulation (Economy line mode): +/- 10%
          Output voltage regulation (Battery mode): +/- 3%
          Output AC waveform (AC mode): Pure Sine wave
          Output AC waveform (battery mode): Pure Sine wave

          Input

          Rated input current (at maximum load): 16A
          Nominal Input Voltages Supported: 100V AC; 110V AC; 115V AC; 120V AC; 127V AC
          Nominal input voltage description: 120V factory default
          Recommended Electrical Service: 20A 120V

          Battery

          Full load runtime: 4 min. (1800w)
          Half load runtime: 12 min. (900w)
          Expandable battery runtime: Extended runtime supported via optional external battery packs
          External battery pack compatibility: BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible)
          Expandable runtime description: Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software
          DC system voltage: 48VDC
          Battery recharge rate (included batteries): Less than 3 hours recharge to 90%
          Replacement battery cartridge (internal UPS battery replacement): RBC94-2U
          Battery Access: Front panel battery access
          Battery replacement description: Hot-swappable, user replaceable batteries

          VOLTAGE REGULATION

          Voltage regulation description: Online, double-conversion power conditioning maintains 2% output voltage regulation during brownouts and overvoltages
          Overvoltage correction: Corrects overvoltages to 150V (0-100% load)
          Undervoltage correction: Corrects undervoltages to 100V at full load (90V at 100V nominal)
          Severe undervoltage correction: Corrects brownouts to 70V (70% load) & 55V (33% load)
          Returns Policy This product is subject to our return policy. Please see our complete return policy for details.
          Standards
          Compliant Standards RoHS
          UNSPSC 39121011
          Warranty - Labor 2 Years
          Warranty - Parts 2 Years
          Warranty Details Connected Equipment Insurance (U.S., Canada & Puerto Rico): $250,000
          Collapse & Return to Top
          Add this product to your cart with selected accessories
          Add To Cart
          Battery Backup Accessories (2 Products)
          Controller Cards (1 Product)
          Environmental Monitoring (1 Product)
          Other Batteries (2 Products)
          Power Distribution (10 Products)
          Power Distribution Units (10 Products)
          Rack Mount Accessories (2 Products)
          Add this product to your cart with selected accessories
          Add To Cart
          Collapse & Return to Top

          07