          • Provides 3000VA, 2700watt(s), 120V power
          • Surge Suppression is Standard
          • Connector(s): Power NEMA L5-30 (F), Power NEMA L5-30 (M), Power NEMA 5-15 (F), Power NEMA 5-20 (F)
          • 9 Outlets
          • 4 minute(s) Battery Runtime at Full Load
          • Attributes include Double conversion online, RJ-11 line protection, RJ-45 line protection

          Ordering Information

          Price:
           
          Tripp Lite Smart Online UPS systems offer high performance power protection ideal for critical server and network equipment in datacenters, computer rooms and network closets. Online, double-conversion Uninterruptible Power Supply (UPS) maintains perfectly regulated output power by continuously converting raw AC input to DC, then re-converting output back to AC. Fully regulated sine wave AC output with +/-2% voltage regulation powers network equipment continuously, even during severe brownouts and overvoltages, all without depleting UPS battery reserves. Maintains battery-derived AC output during power failures with zero transfer time. Extended runtime options available. Interactive LCD interface reports UPS operating mode, detailed UPS and site-power data, plus enables a variety of UPS setup and configuration options. Highly efficient operation in optional economy mode saves BTU heat output and energy costs. Network management interfaces support communications via USB, RS-232, contact-closure and optional SNMPWEBCARD network interface. Built-in DB9 port offers both enhanced RS-232 data and basic contact closure monitoring ability. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. LED display reports UPS operating mode, line power availability, battery mode operation, inverter operation, ECO mode status and output power availability. Audible alarm with push-button momentary alarm-cancel and silent-mode LCD configuration options. Programmable self-test. Fault-tolerant auto-bypass mode. Field-replaceable, hot-swappable internal batteries and external battery packs.
          Collapse & Return to Top
          Connectivity  
          Communication Interface USB
          Communication Interface Serial (RS-232)
          Communication Interface Contact closure
          Connector Power NEMA L5-30 (F)
          Connector Power NEMA L5-30 (M)
          Connector Power NEMA 5-15 (F)
          Connector Power NEMA 5-20 (F)
          # Ports 9
          General  
          Color Black
          Form Factor 3U Rackmount
          Attributes Double conversion online
          Attributes RJ-11 line protection
          Attributes RJ-45 line protection
          Power  
          Battery Run Time (max) 4 minute(s)
          Power Provided 3000 VA
          Power Provided 2700 watt(s)
          Power Provided 120 V
          Surge Suppression Standard
          Actual Weight 74.00 lb(s)
          Compatibility Notes Features

          Selectable 100/110/120/127V output (120V factory preset)
          NEMA L5-30P input, 4 NEMA 5-15/20R, 4 5-15R & 1 L5-30R outlets
          Two switched 4-outlet load banks support remote reboot or programmable load shedding options
          Supports 2% output voltage regulation and zero transfer time in double conversion mode
          Economy mode option offers enhanced efficiency, reduced power consumption and lower BTU emissions
          11 minutes runtime at 50% load (1350W) and 4 minutes at 100% load (2700W) with internal batteries
          BP72V15-2U (limit 1) or BP72V28RT3U (no limit) external battery packs available (some configurations require Tripp Lite's External Battery Configuration Software)
          LCD interface reports operating mode plus 9 selectable screens of UPS data (Load percentage, kW & kVA, Power factor, Input voltage & frequency, Output voltage & frequency, Battery voltage and charge percentage, Minutes runtime, Capacity remaining and Kw/hr. consumption)
          LCD interface also supports 16 screens of UPS configuration and setup options
          4-post installation hardware included, Optional 2POSTRMKITHD enables 2-post rack installation
          Single line TEL / Network surge suppression
          Electronic bypass maintains utility output during a variety of UPS fault conditions
          Frequency regulation / conversion mode offers generator-compatible frequency correction or conversion of frequency from 50 to 60Hz or 60 to 50Hz
          Built-in USB, RS-232, contact-closure and optional SNMPWEBCARD accessory monitoring options
          HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
          Included PowerAlert UPS monitoring software

          LEDS ALARMS & SWITCHES

          LED Indicators: (7) front panel LEDs indicate line power availability, AC to DC conversion, battery mode operation, inverter mode, eco mode operation, bypass mode operation and AC output status
          Front panel: Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, frequency, operating mode, alarm function and a variety of additional options
          Alarms: Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
          Alarm cancel operation: Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available
          Switches: (2) switches control off/on power status and alarm-cancel operation; (2) additional scroll-down and scroll-up / select options enable LCD status viewing and configuration options

          SURGE / NOISE SUPPRESSION

          UPS AC suppression rating: 570 Joules
          UPS AC suppression response time: Instantaneous
          UPS Dataline suppression: (1) line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet
          EMI / RFI AC noise suppression: Yes

          PHYSICAL

          Installation form factors supported with included accessories: 4-post 19 inch rackmount (mounting rail kit included)
          Installation form factors supported with OPTIONAL accessories: 2-post rackmount (2POSTRMKITHD)
          Primary form factor: Rackmount
          Contents UPS, software, USB/Serial/EPO cabling, 4-post rackmount kit, documentation
          Physical Dimensions 5.2"h x 17.5"w x 26"d
          Ports/Connectors Built-in UPS output receptacles: (4) 5-15R outlets; (4) 5-15/20R outlets; (1) L5-30R outlets
          Built-in controllable switched load banks: Two switchable four-outlet load banks
          UPS input connection type: L5-30P
          UPS Input cord length: 10ft (3m)
          Power Notes OUTPUT

          Output Capacity: 3000VA/2700W
          Output power factor: 0.9
          Output Capacity Details: ON LINE MODE - Maximum output capacity ratings are reduced for some nominal voltage settings (127/120V 2700 watts / 115V 2430 watts / 110V 2295 watts / 100V 2160 watts); FREQUENCY REGULATION / CONVERSION MODE - Maximum output ratings are reduced in frequency regulation / conversion mode (127/120V 1890 watts / 115V 1701 watts / 110V 1606 watts / 100V 1512 watts).
          Crest Factor: 3:1
          Nominal Output Voltages Supported: 100V; 110V; 115V; 120V; 127V
          Nominal Voltage details: 120V factory-default nominal voltage
          Frequency compatibility: 50/60 Hz (auto-selectable); Supports 50 to 60 Hz and 60 to 50 Hz conversion
          Frequency compatibility details: ON LINE MODE - Output frequency is automatically configured to match nominal input frequency on startup; Output matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. FREQUENCY REGULATION / CONVERSION MODE: Output is regulated to +/-0.05Hz of selected output frequency input is 40 to 70Hz; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. BATTERY MODE: Output is regulated to +/-0.05Hz.
          Output voltage regulation (line mode): +/- 2%
          Output voltage regulation (Economy line mode): +/- 10%
          Output voltage regulation (Battery mode): +/- 3%
          Output AC waveform (AC mode) Pure Sine wave
          Output AC waveform (battery mode) Pure Sine wave

          INPUT

          Rated input current (at maximum load) 24A
          Nominal Input Voltages Supported: 100V AC; 110V AC; 115V AC; 120V AC; 127V AC
          Nominal input voltage description: 120V factory default
          Input circuit breaker: 40A
          Recommended Electrical Service: 30A, 120V

          BATTERY

          Full load runtime: 4 min. (2700w)
          Half load runtime: 11 min. (1350w)
          Expandable battery runtime: Extended runtime supported via optional external battery packs
          External battery pack compatibility: BP72V15-2U (limit 1); BP72V28RT-3U (multi-pack compatible)
          Expandable runtime description: Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software, see manual for details
          DC system voltage: 72VDC
          Battery recharge rate (included batteries): Less than 3 hours recharge to 90%
          Replacement battery cartridge (internal UPS battery replacement): RBC96-3U
          Battery Access: Front panel battery access
          Battery replacement description: Hot-swappable, user replaceable batteries

          VOLTAGE REGULATION

          Voltage regulation description: Online, double-conversion power conditioning maintains 2% output voltage regulation during brownouts and overvoltages
          Overvoltage correction: Corrects overvoltages to 150V (0-100% load)
          Undervoltage correction: Corrects undervoltages to 100V at full load (90V at 100V nominal)
          Severe undervoltage correction: Corrects brownouts to 70V (70% load) & 55V (33% load)
          Returns Policy This product is subject to our return policy. Please see our complete return policy for details.
          UNSPSC 39121011
          Warranty - Labor 2 Years
          Warranty - Parts 2 Years
          Warranty Details Connected Equipment Insurance (U.S., Canada & Puerto Rico): $250, 000
          Collapse & Return to Top
          Add this product to your cart with selected accessories
          Add To Cart
          Battery Backup Accessories (2 Products)
          Controller Cards (1 Product)
          Environmental Monitoring (1 Product)
          Power Cords (3 Products)
          Power Distribution (6 Products)
          Power Distribution Units (6 Products)
          Rack Mount Accessories (1 Product)
          Add this product to your cart with selected accessories
          Add To Cart
          Collapse & Return to Top

          04