PC Connection Clearance Center. Shop Now!

PC Connection Interactive eCatalog

Messages

          Tripp Lite SmartOnline Expandable 2U Rack Tower UPS System On-line, Double-Conversion, Sine Wave

          More From: Tripp Lite
          Item #: 9517081
          Mfr. Part#: SU3000RTXL2U
          Availability: Temporarily Out-of-Stock
          Est. Ship: Call for next available delivery

          • Provides 2500watt(s) 3000VA power
          • Surge Suppression is Standard
          • Connector(s): Power NEMA 5-20 (F), Power NEMA L5-30 (F), Power NEMA L5-30 (M)
          • 7 Outlets
          • 6 minute(s) Battery Runtime at Full Load
          • Attributes include Double conversion online, Automatic voltage regulation (AVR)

          Online, double-conversion protection for mission critical applications.

          Ordering Information

          Price:
           
          Tripp Lite's SmartOnLine 3000VA/2500 watt on-line, double-conversion UPS system features an optional economy-mode operation with 97% efficiency for reduced power consumption and cooler operation. The UPS actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output. this 2U rack/tower/wallmount-compatible form factor with depth of only 26 inches (66cm) offers ideal protection for critical server, networking and telecommunications equipment in datacenters and remote equipment closets. The unit ships factory configured for 120V operation and offers selectable voltage operation for 100/110/115 and 127V nominal voltages. It connects to a L5-30R utility receptacle (120V, 30A) and provides outlets compatible with common 5-15P, 5-20P and L5-30P equipment or PDU plugs.

          Network management interfaces include a USB port, a DB-9 RS-232 serial port with contact closure support and an expansion slot for an optional SNMPWEBCARD (available separately). The HID-compliant USB interface enables integration with the built-in power management and auto shutdown features of Windows and Mac OS X. Simultaneous detailed monitoring of equipment load levels, self-test data and mains power conditions via all network interfaces at once is supported. PowerAlert monitoring software and complete cabling is included. Integrated two bank PDU switching supports automated load shedding and remote-reboot of connected equipment, and 4-stage metered current monitoring with battery charge status LEDs are also featured. 4-post rackmount accessories are included.
          Collapse & Return to Top
          Actual Weight 68.80 lb(s)
          Compatibility Notes LEDS ALARMS & SWITCHES

          Front panel: LED STATUS DISPLAY - line power (green), online (green), bypass (yellow), on battery (green), overload (red), battery low (yellow) - 4 LED LOAD / BATTERY LEVEL DISPLAY (100%, 75%, 50%, 25%). LCD display panel easily rotates for viewing in rackmount or tower configurations.
          Alarms: multi-function audible alarm with distinctive ring patterns offer notification of backup operation (2 seconds on / 0.5 seconds off), low battery warning (1.25 seconds on / 0.5 seconds off), overload (sounds continuously), UPS fault (4.2 seconds on / 1 second off), input voltage out of frequency (2.1 seconds on / 0.14 seconds off) and high input voltage (2.1 seconds on 0.07 seconds off)
          Switches: power off/on switch to enable system turn on (press ON switch), UPS battery test (press ON switch during normal AC operation), buzzer silence (press ON switch during battery operation) and OFF (press OFF switch) - all switch functions require that the switch be pressed and held for longer than 2 seconds, but less than 4 seconds

          SURGE / NOISE SUPPRESSION

          AC surge suppression: 504 joules
          AC suppression response time: Instantaneous
          EMI / RFI AC noise suppression: Yes
          Connectivity
          # Ports 7
          Communication Interface Contact closure, Serial (RS-232), USB
          Connector Power NEMA 5-20 (F), Power NEMA L5-30 (F), Power NEMA L5-30 (M)
          Contents UPS System, PowerAlert software, cabling, 4-post rackmount installation brackets, documentation
          General
          Attributes Automatic voltage regulation (AVR), Double conversion online
          Color Black
          Form Factor 2U Rackmount, Tower, Wall-mounted
          Physical Dimensions 3.5"h x 17.3"w x 26"d
          Ports/Connectors (6) NEMA 5-15/20R outlets
          (1) NEMA L5-30R outlet
          (1) NEMA L5-30P input, 10ft cord
          (1) DB-9 management port with contact closure supported
          (1) USB port (HID enabled)
          (1) Expansion slot (available)
          (1) Emergency Power Off port (EPO)
          Power
          Battery Run Time (max) 6 minute(s)
          Power Provided 2500 watt(s), 3000 VA
          Surge Suppression Standard
          Power Notes Voltage compatibility: 100/110/115/120/127VAC (factory configured for 120V)
          Frequency compatibility: 50/60Hz

          Output

          Output capacity: 3000VA/2500 watts (120/127V nominal) / 2400 watts (100/110/115V nominal)
          Output voltage regulation: +/- 2% in standard double-conversion mode (+10% / -12% in economy mode)
          Output frequency regulation: frequency is regulated to 50/60Hz +/-0.05Hz. Frequency conversion from 50 to 60Hz and 60 to 50Hz is supported (output watt capacity is reduced by 25% in when frequency conversion is in use).

          Input

          Maximum input: 24A (120V)
          Recommended electrical service: 100/110/115/120/127VAC, 30A

          Battery and Runtime

          Full load runtime, internal batteries: 6 minutes (2500W)
          Half load runtime, internal batteries: 15 minutes (1250W)
          Expandable battery runtime: runtime is expandable with optional BP72V15-2U (limit 1) and BP72V28RT3U (limit 2) external battery packs available separately
          DC system voltage: 72VDC
          Battery recharge rate: 6.8 hours to 90%
          Replacement Battery Cartridge: RBC96-2U

          Voltage Regulation

          Description: double conversion mode output is regulated within 2% of selected nominal voltage; economy mode, output is regulated within -12% / +10% of selected nominal voltage.
          Overvoltage correction: corrects overvoltages to 144V
          Brownout correction: corrects undervoltages to 80V (70V at less than 70% load)
          Returns Policy This product is subject to our return policy. Please see our complete return policy for details.
          UNSPSC 39121011
          Warranty - Labor 2 Years
          Warranty - Parts 2 Years
          Warranty Details $250,000 Connected Equipment Insurance (USA/Canada only)
          Collapse & Return to Top
          Add this product to your cart with selected accessories
          Add To Cart
          Battery Backup Accessories (1 Product)
          Controller Cards (1 Product)
          Environmental Monitoring (1 Product)
          Other Batteries (2 Products)
          Power Distribution (4 Products)
          Power Distribution Units (4 Products)
          Rack Mount Accessories (2 Products)
          Add this product to your cart with selected accessories
          Add To Cart
          Collapse & Return to Top

          07